We supply Light Curtain, which is a kind of switching mode power supply units. The curtain provides the power supply function through components such as capacitors, inductors, transformers and switches that are in one of two states, on or off.

Safety Light Curtain
Generates a multiple-beam infrared pattern for extraordinary sensitivity to small objects
Detects objects as small as 5.6 mm and extremely flat objects that pass anywhere through the light screen.
Responds in 0.8 to 3.2 milliseconds—faster than comparable products, even at its slowest response speed
Enables automated systems to operate at peak efficiency.
Ideal for die-protection (part ejection verification), small part or pill counting, parcel handling and sorting by height.
Available in 67, 143 or 295 mm lengths and two sensing ranges: 100 to 200 mm and 300 mm to 2 m.
Features rugged silver anodized housing with IP65 rating.
Uses integrated T-slot mounting channel for unique mounting flexibility.
Banner Safety
  • Designed for lower-risk applications such as bump or bruise, knock-down, trapping but not crushing, or minor cuts and abrasions
  • Features simple, two-piece integrated system with no control box
  • Detects narrow objects, such as a hand or ankle
  • Offered with 30 mm resolution and 15 m range
  • Provides economical, compact optical safeguarding
  • Meets Type 2 requirements per IEC61496-1/-2 and Category 2 per EN954-1
  • Available in trip (auto reset) or latch (manual reset) models
  • Offers optional lens shields and enclosures for added durability
  • Allows combining up to four systems of any length and resolution
  • Guards multiple areas with minimal wiring and interfacing, without dual or quad controllers
  • Offers same features as standard EZ-SCREEN systems with 14 and 30 mm resolution
  • Does not increase the overall response time significantly
  • Allows up to 53 m of cabling between receivers, depending on the number of receivers and the length of the machine interface/power cable
  • Available with nickel-plated ESD-safe housing for protection against electrostatic discharges or with standard nickel-plated housing
  • Offers optional lens shields and enclosures for added durability
  • Very flexible – protective and warning fields can take nearly any shape
  • Capable of switching “on-the-fly” between eight pre-configured field pairs
  • Adjustable response time (80 ms to 640 ms)
  • Selectable resolutions 30mm, 40mm, 50mm, 70mm, 150mm
  • Two models available: AG4-4E with a maximum 4 meter range, AG4-6E with a maximum 6.25 m range
  • Cost effective for difficult safeguarding solutions
  • Interfacing options include: SC22-3/-3E Safety Controller, UM-FA-9A/-11A Universal Input Safety Module, MMD-TA-11A-12B Dual Controller Muting Module
  • Compact design, simple installation and easy-to-use software provide efficient integration into work zones
  • Rugged, die-cast aluminum housing withstands the rigor of factory floors.
  • Simple, two-piece integrated system has no control box.
  • High-resolution 14 and 30 mm point-of-operation systems detects fingers, hands and ankles.
  • Type 2 models with 30 mm resolution are available for lower-risk applications.
  • Point and Grid systems allow one-, two-, three- or four-beam perimeter and access guarding.
  • Superior optical design and finely focused ±2.5° beam make systems extremely easy to align and maintain.
  • Status indicators and diagnostics show when alignment is complete and installation is correct.
  • Redundant microprocessor-controlled, self-checking design of Type 4 models exceed control reliability requirements and is certified per CE (Type 4/Category 4) and cULus (NIPF, UL 61496, UL1998).
  • Unique cascading models allow up to four systems of any length and resolution to be wired together to form a single safety device.
  • Systems have ranges up to 70 m, with power and range for all types of applications including long-range perimeter guarding.
  • Compact, rugged and lightweight housing resists impact, twisting and abusive environments
  • Modules work with Banner STB self-checking touch buttons or can be retrofitted with existing mechanical palm buttons to create a complete, ergonomic two-hand control system.
  • To ensure reliability, modules have a diverse-redundant microcontroller circuit and multiple redundant, force-guided (mechanically linked) output contacts.
  • Anti-tiedown logic requires that both touch buttons are activated within one-half second of each other.
  • Ac and dc voltages are available: 24V ac/dc, 115V ac/24V dc or 230V ac/24V dc.
  • Modules are available with two or four normally open (NO) safety outputs.
  • Non-safety auxiliary outputs are available on some models.
  • Modules meet Safety Category 4 per ISO 13849-1 (EN 954-1) and functional Type IIIC two-hand control per EN 574.
  • Removable terminal blocks allow convenient wiring and exchange of modules without rewiring.
  • Optional mute inputs allow release of actuating buttons during the non-hazardous portion of the machine cycle.
  • Available kits include module and two STB touch buttons.
  • STB touch buttons are far more ergonomic than mechanical and difficult-to-activate capacitive buttons.
  • Uses an RJ45 Ethernet connector and standard or crossover-style cordsets to communicate via Ethernet communications protocols
  • 32 configurable virtual status outputs with "Auto Configuration" option
  • Network access to the Fault Log and System/Network parameters
  • 22 input terminals can monitor both contact-based or PNP solid-state outputs from Banner devices or any other manufacturers
  • Each input can be a non-safety input, or configured for Control Reliability or Category 2, 3 or 4 safety circuit performance per ISO 13849-1
  • 3 pairs of solid-state safety outputs rated at 0.5A each (24V dc) with selectable one- or two-channel external device monitoring and ON-delay or OFF-delay
  • 10 configurable auxiliary status outputs track inputs, outputs, lockout, I/O status and other functions
  • Live Display and a Fault Log provide real-time system and fault history identification
  • Controller is designed to meet stringent standards including Safety Integrity Level (SIL) 3 per IEC 62061 and IEC 61508, and Category 4 Performance Level (PL e) per ISO 13849-1
  • Quick-disconnect (QD) cables allow safety devices to be installed, replaced or moved quickly, minimizing down-time.
  • Euro-, Mini and Micro-style cables are available.
  • Choose straight or right-angle connectors.
  • Models are available with single or double-ended QD connectors, or as unterminated bulk cable.
  • Splitter cables are available for powering two devices with one cable.